PLUGIN catalogue 2018

All surfaces should be cleaned before mounting. After rst vacuum drop down, screws may be tightened again. Recommended surface roughness < Ra 0,8 - Tightening torque : 1,2 N.m Modules may be delivered as spare parts or fully assembled and tested on ange. Leakrate : < 1.10-8 mbar.l/s - Temperature Range : -40°C / +80°C The products of the ERVAC range are totally removable and reversible. 1 - Dismount the 2 screws on the connector located at the vacuum side 2 - Properly clean the mounting ange with iso-propyl alcohol 3 - Properly clean the at viton gasket with iso-propyl alcohol 4 - Place the at Viton gasket in the bottom of the machined window (Air side) 5 - Place the ERVAC against the at viton gasket (Air side) 6 - Tighten the 2 screws on the vacuum side by respecting the tightening torque (see below) Mounting process 6