PLUGIN catalogue 2018

ERVAC DVI-I - Technical data 45 Technical Data Mechanical performance Additional general speci cations are: Plug: -LFH (Low Force Helix) style contacts -fully shielded RFI/EMI can -grounding detents on mating shell -solder tails for cable termination -positive retention jackscrew: thread 4-40 UNC-2A Receptacle: -high cycle, dual beam, LFH shrouded contacts -polarization achieved by a "D" shaped housing/shield -single piece shield with integral ground leg -shield protrudes for ESD considerations -solder tails for thru hole board mount -plastic retention pegs -jackposts: # 4-40 UNC-2A&B threads. ITEM TEST CONDITION REQUIREMENT Mating force One pair per ANSI/EIA-364-13 - Insertion speed: 1 inch (25,4mm) per minute 10.0 lbf (4,5 kgf) maximum Unmating force Mated pair per ANSI/EIA-364-13 - Withdraw speed: 1 inch (25,4mm) per minute 2,2 lbf (1,0 kgf) minimum - 8,8 lbf (4,0 kgf) maximum Receptacle contact retention Individual contact 1,0 lbf (0,45 kgf) minimum Receptacle key retention individual key 2,0 lbf (0,90 kgf) minimum Plug contact retention Push out frommating face - Individual contact 10 lbf (4,5 kgf) minimum Plug key retention Push out frommating face - individual key 10 lbf (4,5 kgf) minimum Durability Automatic cycling : 100 cycles per ANSI/EIA-364-09 at 100 +/- 50 cycles per hour Contact resistance per EIA-364-23 : 10 m Ω maximum change from initial per contact pair - All samples to be mated - Shell resistance : 50 mΩmaximum (change from initial reading) Vibration 15 minutes / axis per ANSI/EIA-364-28 method 5A No discontinuities at 1 µ s or longer 'each contact) when continuity is tested per EIA- 364-46 Shock (mechanical) Per ANSI/EIA-364-27, condition A (speci ed pulse) No discontinuities at 1 µ s or longer 'each contact) when continuity is tested per EIA- 364-46 Cable pullout force Tes for cable strain relief & termination integrity. Cable subjected to 25,0 lbf (11,3 kgf) static load for one minute while monitoring continuity. Isolate plug & receptacle interface from load. No discontinuities greater than 1 µs. Board insertion force 10 lbf (4,5 kgf) maximum Cable ex 100 cycles in each of 2 planes - Dimension X = 3,7x cable diameter per ANSI/EIA-364- 41 condition I No discontinuities greater than 1 µs allowed during exing on contacts or shields per EIA-364-46 - Dielectric withstanding voltage and insulation resistance tested per requirements of section 5.1 .050" pitch terminals : 75 grams typical .075" pitch terminals : 90 grams typical Ground plane : 100 grams typical Thread torque Mounted to panel; Test to failure; Tighten jackposts with torque gage until threads are stripped and jackpost turns freely 5,0 lbf in (5,76 kgf cm) minimum Normal force For reference only

RkJQdWJsaXNoZXIy MTEyODU=