ERVAC Optical ber - Technical data 42 Step index : from 100 to 1 000 µm core Optical aperture : 0.37 or 0.22 For any wavelength : UV or UV+visible or UV + IR or very large band Max insertion loss : < 3 dB @ 850 nm ( 2 dB for a 600 µm ber ) Single-mode : 1 310 or 1 550 nm Single-mode with low wavelength : 450 , 600 , 630 , 750 , 780 , 820 , 980 or 1 060 nm Gradient index : GI 50/125 , GI 62.5/125 Step index : LCH 125 or 50 ( visible + IR ) Max insertion loss : < 1 dB @1 550 nm with SMF28 type single-mode ber Step index : from 100 to 1 000 µm core Optical aperture : 0.37 or 0.22 For wavelength UV or UV+visible or UV + IR or very large band UV or UV+visible or UV + IR or very large band Max insertion loss : < 3 dB @ 850 nm ( 1.5 dB @ 850 nm for a 200 µm ber ) Single-mode : 1 310 or 1 550 nm Single-mode with low wavelength : 450 , 600 , 630 , 750 , 780 , 820 , 980 or 1 060 nm Gradient index : GI 50/125 , GI 62.5/125 FC/PC Max insertion loss : < 1 dB @1 550 nm ( 0.3 dB @ 1 550 nm with SMF28 type single-mode ber ) FC/APC Max insertion loss : < 1.5 dB @ 1 550 nm ( 0.7 db @1 550 nm with SMF28 type single-mode ber ) Single-mode polarization maintaining ber ( PANDA type ) : 1 310 or 1 550 nm Single-mode polarization maintaining ber ( PANDA type ) low wavelength : 450 , 600 , 750 , 780 , 820 , 980 or 1 060 nm SMAM/M FC/PC or FC/APC M/M FC/PC or FC/APC M/M with polarizationmaintaining ber OPTICAL CONNECTOR VARIATIONS vs OPTICAL FIBER RANGE SMA F/F FC/PC F/F Technical speci cations ERVAC® Optical contact Body Material Aluminium blue anodized Stainless steel Vacuum level Leak rate Tightening torque Total Mass Loss Collected Volatile Condensable Materials > 1.10 -8 mbar < = than 1.10 -8 mbar.l/s 1,2 N.m TML < 0,1% CVCM < 0,01 % wo SMA or FC/PC type Optical Fibers in one standard ERVAC® module. A number of ber optic links have to go through a pannel separating two volumes hermetically insulated (vacuum, liquid, gas, temperature, radiations, etc.). A ber optic connexion is generally made of two male connec- tors with a female coupling part. It is this coupling part, with FC/PC, FC/APC or SMA interface, which will be the base of this range of hermetic feedthrough. A standard coupling part between two connectors is a precision part which allows the alignment of the connectors ferrules. In the hermetic feedthrough this coupling part is made longer and a piece of ber is glued inside to obtain an hermetic optical path. This ber is chosen to match the bers to be connected at each end of the feedthrough. The hermeticity between the feedthrough itself and the panel is obtained by a classi- cal ange and gasket solution.

RkJQdWJsaXNoZXIy MTEyODU=